    Basic Info

    Type:Home Alarm

    Signal Transmission:Wired Alarm

    Working Mode:Active

    Certification:CE,  RoHS

    Application:Indoor

    Sensor Type:Electric Alarm

    Working Principle:Electro-Optical Type

    Transmission Mode:Wireless

    Receive Frequency:Zigbee

    Usage:Gas

    Color :White:5inch


    Features

    New type With Voice
    Adopt MCU control
    Adopt SMT mounted
    Easy installation with a metal bracket
    Detect LPG and LNG include city gas
    Ideal for all kitchens
    Excellent reliability & high stability
    Self test function
    Less affected by other organic solvent
    High Accuracy

    Specifications:
    Sensor: Catalytic sensor
    Detected gas: Natural gas,
    Operating voltage: 220VAC or 110VAC, 12VDC-24VDC
    Operating Temperature: -10'C - +50'C
    Working environment: Humidity ≤ 97% RH
    Alarm density: Coal gas: 1000~5000ppm, Natural gas: 1000ppm~5000ppm
    Liquid petroleum gas: 1000~10000ppm,
    Alarm sound: 85dB/3m
    Linkage function: Can link with fan, manipulator, shut-off valve(optional)

    Networking: Wired networking: (NO, NC)(optional)
    Wireless networking: 315MHz/433MHz (2262 OR 1527)(optional)1. Fitting Locations:

    According to specific gravity of natural gas to install gas leakage alarm


    1. Natural gas and coal gas: Its specific gravity is lighter than air, so it suspends on the ceiling. Therefore, it is advisable to locate the alarm 30cm below the ceiling at a distance about 1.5m away from gas appliance.
    2. Liquid petroleum gas: Its specific gravity is heavier than air, so it sinks down on the bottom. Therefore, it is advisable to locate the alarm 30cm above the floor at a distance of 1 meter away from a gas appliance.


    When the detector is ringing with loud sound to remind people, pls open windows to discharg the combustible gas, and enhances the fresh air and oxygen density.

    Required to attention:
    1. Do not face it to oil smoke and steam of cooking range
    2. Do not install it at the airiness area
    3. Do not be obstructed by window curtain or cabinet
    4. Wired networking(Optional):
    4.1. Red wire =Positive power input
    This wire must be connected to a permanent positive source.

    Black wire = Negative power input.
    This wire must be connected to a permanent negative source.

    4.2. Yellow wire = Relay (Common) COM contact.
           Blue wire = Relay (Normally open) NO contact.
           White wire = Relay Normally closed) NC contact.

    4.3. Connect with exhaust fan
    Connect both blue and yellow wire with exhaust switch.

    Instructions:
    1), The gas detector should be installed at the position of 1.5 meters radius from the gas source, and well-ventilated place

    2), If the gas is heavier than the air, the gas detector should be installed higher 0.3-1.2m than the ground; If the gas is lighter

    The above is for reference only
    Shenzhen Chuangan Security Electronics Co., ltd
    WhatsApp / WeChat: +8618033436303


Send your message to this supplier
To:  

Shenzhen Chuangan Electronic Co.,Ltd

* Content:  

For better quotations, include:

- A self introduction

- Special requests, if any

Quantity:  

  
Not exactly what you want? One request, multiple quotations Get Quotations Now >>
Related Searches :